Cat C9 | DE300E0 diesel generator set

Power Ratings

RatingkVAekW
Standby300 kVA240 ekW
Prime275 kVA220 ekW

Full Technical Information

Open PDF Specification

Overview, Engine and Ratings

Bore x Stroke
112mm x 149mm (4.4in x 5.9in)
Displacement
8.8 L (538 in³)
Compression Ratio
16.1:1
Governor
Electronic ADEM™ A4 - G3 Class* capable

Package Performance

Details
Performance StandbyPrime
Frequency 50 Hz
Genset Power Rating 300 kVA275 kVA
Genset power rating with fan @ 0.8 power factor 240 ekW220 ekW
100% load with fan, L/hr (gal/hr) 64.3 (17)59 (15.6)
75% load with fan, L/hr (gal/hr) 48.4 (12.8)44.6 (11.8)
50% load with fan, L/hr (gal/hr) 34.4 (9.1)32.1 (8.5)
25% load with fan, L/hr (gal/hr) 20.8 (5.5)19.6 (5.2)
Radiator air flow restriction (system), kPa (in. Water) 0.12 (0.48)0.12 (0.48)
Radiator air flow, m3/min (cfm) 438 (14443)438 (14443)
Engine coolant capacity, L (gal) 13.9 (3.7)13.9 (3.7)
Radiator coolant capacity, L (gal) 43 (11.5)43 (11.5)
Total coolant capacity, L (gal) 56.9 (15.2)56.9 (15.2)
Combustion air inlet flow rate, m³/min (cfm) 16.5 (584)15.7 (557)
Max. Allowable Combustion Air Inlet Temp, °C (°F) 48 (118)48 (118)
Exhaust stack gas temperature, °C (°F) 551 (1024)545 (1012)
Exhaust gas flow rate, m³/min (cfm) 48.2 (1704)45.3 (1600)
Exhaust system backpressure (maximum allowable) kPa (in. water) 10.0 (40.0)10.0 (40.0)
Heat rejection to jacket water, kW (Btu/min) 115 (6565)110 (6255)
Heat rejection to exhaust (total) kW (Btu/min) 217 (12320)200 (11341)
Heat rejection to aftercooler, kW (Btu/min) 46 (2592)40 (2280)
Heat rejection to atmosphere from engine, kW (Btu/min) 27 (1559)25.3 (1441)
LEHE1616-03 1/2
NOx, mg/Nm³ (g/hp-hr) 3322 (6.8)3638 (7.3)
CO, mg/Nm³ (g/hp-hr) 892 (1.8)687.5 (1.42)
HC, mg/Nm³ (g/hp-hr) 11.9 (0.03)13.1 (0.03)
PM, mg/Nm³ (g/hp-hr) 28.4 (0.07)30.4 (0.08)
Voltages 230V380V400V415V
Motor starting capability @ 30% Voltage Dip 827 skVA746 skVA827 skVA886 skVA
Temperature Rise 125°C125°C125°C125°C

Weights and Dimensions

Length
2,662 mm (89 in)
Width
1,030 mm (41 in)
Height
1,754 mm (69 in)
Weight
2,110 kg (4,652 lb)
Details

Note: General configuration not to be used for installation. See general dimension drawings for detail.

Applicable Codes and Standards

Details
AS1359, CSA C22.2 No100-04, UL142, UL489, UL869, UL2200, NFPA37, NFPA70, 1
MG1-33, 2006/95/EC, 2006/42/EC, 2004/108/EC. 2
of the normal source power. Average power output is 70% of the standby power nominal emissions data shown is subject to instrumentation, measurement,
rating. Typical operation is 200 hours per year, with maximum expected usage of facility and engine to engine variations. Emissions data is based on 100% load
output is 70% of the prime power rating. Typical peak demand is 100% of prime 3
hour in 12. Overload operation cannot exceed 25 hours per year is based on a 40° C ambient per NEMA MG1-32.
RATINGS: Ratings are based on SAE J1349 standard conditions. These ratings Governing Class capability as per ISO8528-5.Consult your local Cat dealer for

Commercial Application

Standby and prime power for buildings, manufacturing, data centers and distributed infrastructure. The card helps quickly verify configuration, frequency, power, dimensions and delivery availability for a specific site.