Cat C4.4 | DE110E2 diesel generator set
Power Ratings
| Rating | kVA | ekW |
|---|---|---|
| Rating 1 | 110 kVA | 88 ekW |
| Rating 2 | 125 kVA | 100 ekW |
| Rating 3 | 100 kVA | 80 ekW |
| Rating 4 | 113 kVA | 90 ekW |
Full Technical Information
Open PDF SpecificationOverview, Engine and Ratings
- Bore x Stroke
- 105.0 mm x 127.0 mm (4.1 in x 5.0 in)
- Displacement
- 4.4 L (268.5 in³)
- Compression Ratio
- 18.3:1
- Governor
- Electronic
Package Performance
Details
Performance
StandbyPrime
Frequency
50 Hz60 Hz50 Hz60 Hz
Genset Power Rating
110 kVA125 kVA100 kVA113 kVA
Genset power rating with fan @ 0.8 power factor
88 ekW100 ekW80 ekW90 ekW
Fuel Tank Capacity, litres (US gal)
250 (66.0)
100% load with fan, L/hr (gal/hr)
23.8 (6.3)28.5 (7.5)21.7 (5.7)25.7 (6.8)
75% load with fan, L/hr (gal/hr)
18.0 (4.8)21.5 (5.7)16.5 (4.4)19.6 (5.2)
50% load with fan, L/hr (gal/hr)
12.6 (3.3)15.2 (4.0)11.7 (3.1)14.1 (3.7)
Radiator air flow, m³/min (CFM)
187.8 (6632)244.2 (8624)187.8 (6632)244.2 (8624)
Total coolant capacity, L (gal)
17.5 (4.6)
Max. Combustion Air Intake Restriction, kPa (in water)
8.0 (32.1)
Combustion air inlet flow rate, m³/min (CFM)
6.3 (221)7.8 (275)6.0 (212)7.8 (274)
Max. Allowable Combustion Air Inlet Temp, °C (°F)
50 (122)
Exhaust stack gas temperature, °C (°F)
543 (1009)574 (1065)514 (957)517 (963)
Exhaust gas flow rate, m³/min (CFM)
16.3 (576)20.4 (720)15.2 (537)18.4 (650)
Exhaust system backpressure (maximum allowable), kPa (in water)
18.0 (72.3)15.0 (60.2)18.0 (72.3)15.0 (60.2)
Heat rejection to jacket water, kW (BTU/min)
50.7 (2883)64.0 (3640)46.1 (2622)57.7 (3281)
Heat rejection to alternator, kW (BTU/min)
7.8 (444)8.3 (472)7.8 (444)8.3 (472)
Heat rejection to atmosphere from engine, kW (BTU/min)
15.3 (870)17.7 (1007)13.7 (779)15.7 (893)
LEHE0706-06
1/2
Duty Cycle
StandbyPrime
Phase
3-Phase3-Phase
Voltages, V
200/115220/127380/220400/230415/240200/115220/127380/220400/230415/240
Current, Amps
318289167159153289262152144139
Temperature Rise, @ 40°C
163163163163163125125125125125
Temperature Rise @ 40°C
163163163163163163163163
Voltages, V
208/120 220/127 220/110 240/139 240/120 380/220 440/254 480/277 208/120 220/127 220/110 240/139 240/120 380/220 440/254 480/277
Current, Amps
347328328300.7300.7189.9164150.4313.7296.5296.5271.8271.8171.7148.3135.9
Weights and Dimensions
- Length
- 2,089 mm (82.2 in)
- Width
- 1,120 mm (44.1 in)
- Height
- 1,375 mm (54.1 in)
- Weight
- 1,129 kg (2,490 lb)
Details
Note: General configuration not to be used for installation. See general dimension drawings for detail.
Applicable Codes and Standards
Details
AS1359, IEC60034-1, ISO 3046, ISO 8528, NEMA MG1-33, EAC, CE, UKCA.
1
Commercial Application