Skip to content

Cat C32 High Performance Propulsion Engines

Power Ratings

RatingkVAekW
Standby1,100 kVA880 ekW
Mission Critical1,100 kVA880 ekW
Prime1,000 kVA800 ekW
Continuous910 kVA728 ekW

Full Technical Information

Open PDF Specification

Overview, Engine and Ratings

Bore – mm (in)
145 (5.7)
Stroke – mm (in)
162 (6.4)
Displacement – L (in3)
32 (1952.76)
Compression Ratio
15.0:1
Aspiration
TA
Governor Type
ADEM™ A4

Package Performance

Details
Performance StandbyMission CriticalPrime
Frequency 50 Hz50 Hz50 Hz
Gen set power rating with fan 1000 ekW1000 ekW880 ekW
Gen set power rating with fan @ 0.8 power factor 1250 kVA1250 kVA1100 kVA
100% load with fan – L/hr (gal/hr) 252.3 (66.7)252.3 (66.7)220.7 (58.3)
75% load with fan – L/hr (gal/hr) 185.5 (49.0)185.5 (49.0)164.8 (43.5)
50% load with fan – L/hr (gal/hr) 128.4 (33.9)128.4 (33.9)116.1 (30.7)
25% load with fan – L/hr (gal/hr) 75.0 (19.8)75.0 (19.8)68.7 (18.1)
Radiator air flow restriction (system) – kPa (in. water) 0.12 (0.48)0.12 (0.48)0.12 (0.48)
Radiator air flow – m3/min (cfm) 825825825
Engine coolant capacity – L (gal) 55 (14.5)55 (14.5)55 (14.5)
Radiator coolant capacity – L (gal) 171 (45.0)171 (45.0)171 (45.0)
Total coolant capacity – L (gal) 226 (59.5)226 (59.5)226 (59.5)
Combustion air inlet flow rate – m3/min (cfm) 74.2 (2619.0)74.2 (2619.0)67.9 (2397.4)
Exhaust stack gas temperature – °C (°F) 464.6 (868.3)464.6 (868.3)440.6 (825.2)
Exhaust gas flow rate – m3/min (cfm) 192.9 (6812.8)192.9 (6812.8)170.3 (6012.6)
Heat rejection to jacket water – kW (Btu/min) 340340308
Heat rejection to exhaust (total) – kW (Btu/min) 871871752
Heat rejection to aftercooler – kW (Btu/min) 241241196
Heat rejection from alternator – kW (Btu/min) 525243
NOx mg/Nm3 (g/hp-h) 2928.1 (5.80)2928.1 (5.80)3185.5 (6.15)
CO mg/Nm3 (g/hp-h) 229.6 (0.46)229.6 (0.46)209.4 (0.42)
PM mg/Nm3 (g/hp-h) 11.9 (0.03)11.9 (0.03)11.3 (0.03)
NOx mg/Nm3 (g/hp-h) 3543.0 (7.02)3543.0 (7.02)3854.5 (7.45)
HC mg/Nm3 (g/hp-h) 10.7 (0.02)10.7 (0.02)10.5 (0.02)

Weights and Dimensions

Length
1,100 mm (880 in)
Width
1,100 mm (880 in)
Height
1,000 mm (800 in)
Weight
910 kg (728 lb)
Details

Note: For reference only. Do not use for installation design. Contact your account manager for precise weights and dimensions.

Ratings and Definitions

Standby
Output available with varying load for the duration of the interruption of the normal source power. Average power output is 70% of the standby power rating. Typical operation is 200 hours per year, with maximum expected usage of 500 hours per year.
Mission Critical
Output available with varying load for the duration of the interruption of the normal source power. Average power output is 85% of the mission critical power rating. Typical peak demand up to 100% of rated power for up to 5% of the operating time. Typical operation is 200 hours per year, with maximum expected usage of 500 hours per year.
Prime
Output available with varying load for an unlimited time. Average power output is 70% of the prime power rating. Typical peak demand is 100% of prime rated ekW with 10% overload capability for emergency use for a maximum of 1 hour in 12. Overload operation cannot exceed 25 hours per year.
Continuous
Output available with non-varying load for an unlimited time. Average power output is 70-100% of the continuous power rating. Typical peak demand is 100% of continuous rated kW for 100% of the operating hours. C32-PGCG LEHE1263-00 (4-17)

Commercial Application