Bore x Stroke
105.0mm x 127.0mm (4.1in x 5.0 in)
Displacement
3.3 L (201.4 in³)
Compression Ratio
19.25:1

Package Performance

Details
Performance StandbyPrime
50 Hz 60 Hz50 Hz60 Hz
Frequency 50 Hz60 Hz50 Hz60 Hz
Genset Power Rating 33.0 kVA37.5 kVA30.0 kVA33.8 kVA
Genset power rating with fan @ 0.8 power factor 26.4 kW30.0 kW24.0 kW27.0 kW
Fuel Tank Capacity, litres (US gal) 161 (42.5)
100% load with fan, L/hr (gal/hr) 7.7 (2.0)9.1 (2.4)6.9 (1.8)8.1 (2.1)
75% load with fan, L/hr (gal/hr) 5.7 (1.5)6.8 (1.8)5.2 (1.4)6.2 (1.6)
50% load with fan, L/hr (gal/hr) 4.1 (1.1)5.0 (1.3)3.8 (1.0)4.7 (1.2)
Radiator air flow restriction (system), kPa (in. Water) 6.5 (26.1)
Radiator air flow, m³/min (cfm) 62.6 (2211)84.8 (2995)62.6 (2211)84.8 (2995)
Total coolant capacity, L (gal) 10.2 (2.7)
Combustion air inlet flow rate, m³/min (cfm) 2.2 (76)2.6 (91)2.2 (76)2.6 (92)
Max. Allowable Combustion Air Inlet Temp, °C (°F) 50 (122)
Exhaust stack gas temperature, °C (°F) 520 (968)530 (986)500 (932)520 (968)
Exhaust gas flow rate, m³/min (cfm) 5.8 (205)6.6 (233)5.7 (201)6.4 (226)
Exhaust system backpressure (maximum allowable), kPa (in. water) 8.0 (2.4)10.0 (3.0)8.0 (2.4)10.0 (3.0)
Heat rejection to jacket water, kW (Btu/min) 18.0 (1024)22.0 (1251)16.0 (910)18.0 (1024)
Heat rejection to alternator, kW (Btu/min) 3.8 (216)4.4 (250)3.8 (216)4.4 (250)
Heat rejection to atmosphere from engine, kW (Btu/min) 9.8 (557)10.4 (591)8.1 (461)8.8 (500)
LEHE1061-01 1/2
Voltages 415V400V380V220V480V380V240V440V
Current, amps 4648508745538949
Temperature Rise, °C 163/27163/27163/27163/27125/40163/27125/40163/27

Weights and Dimensions

Length
1,540 mm (60.6 in)
Width
970 mm (38.2 in)
Height
1,361 mm (53.6 in)
Weight
838 kg (1,847 lb)
Details

Note: General configuration not to be used for installation. See general dimension drawings for detail.

Applicable Codes and Standards

Details
AS1359, CSA C22.2 No100-04, UL142, UL489, UL869, UL2200, NFPA37, NFPA70, 1
MG1-33, 2006/95/EC, 2006/42/EC, 2004/108/EC. 2
of the normal source power. Average power output is 70% of the standby power nominal emissions data shown is subject to instrumentation, measurement,
rating. Typical operation is 200 hours per year, with maximum expected usage of facility and engine to engine variations. Emissions data is based on 100% load
output is 70% of the prime power rating. Typical peak demand is 100% of prime 3
hour in 12. Overload operation cannot exceed 25 hours per year is based on a 40° C ambient per NEMA MG1-32.

Commercial Application

Standby and prime power for buildings, manufacturing, data centers and distributed infrastructure. The card helps quickly verify configuration, frequency, power, dimensions and delivery availability for a specific site.