Cat 3516E (60 Hz) diesel generator set

Power Ratings

RatingkVAekW
Standby3,438 kVA2,750 ekW
Mission Critical3,438 kVA2,750 ekW
Prime3,125 kVA2,500 ekW

Full Technical Information

Open PDF Specification

Overview, Engine and Ratings

Bore – mm (in)
170 (6.69)
Stroke – mm (in)
215 (8.46)
Compression Ratio
14.7:1
Aspiration
TA
Governor Type
ADEM™ A5

Package Performance

Details
Performance StandbyMission CriticalPrime
Frequency 60 Hz60 Hz60 Hz
Gen set power rating with fan 2750 ekW2750 ekW2500 ekW
3438 kVA 3438 kVA3125 kVA
Emissions EPA ESE (TIER 2) EPA ESE (TIER 2) EPA ESE (TIER 2)
100% load with fan – L/hr (gal/hr) 720.4 (190.3)720.4 (190.3)649.4 (171.5)
75% load with fan – L/hr (gal/hr) 549.7 (145.2)549.7 (145.2)508.7 (134.4)
50% load with fan – L/hr (gal/hr) 401.7 (106.1)401.7 (106.1)372.8 (98.5)
25% load with fan – L/hr (gal/hr) 235.1 (62.1)235.1 (62.1)220.1 (58.1)
Radiator air flow – m3/min (cfm) 268826882688
Engine coolant capacity – L (gal) 233.0 (61.6)233.0 (61.6)233.0 (61.6)
Radiator coolant capacity – L (gal) 184.0 (48.6)184.0 (48.6)184.0 (48.6)
Total coolant capacity – L (gal) 417.0 (110.2)417.0 (110.2)417.0 (110.2)
Combustion air inlet flow rate – m3/min (cfm) 229.2 (8093.3)229.2 (8093.3)215.7 (7616.9)
Exhaust stack gas temperature – °C (°F) 493.0 (919.3)493.0 (919.3)472.7 (882.9)
Heat rejection to jacket water – kW (Btu/min) 894894827
Heat rejection to exhaust (total) – kW (Btu/min) 284928492514
Heat rejection to aftercooler – kW (Btu/min) 941941844
Heat rejection from alternator – kW (Btu/min) 126126112
NOx mg/Nm3 (g/hp-h) 2319.2 (5.00)2319.2 (5.00)2275.1 (4.82)
HC mg/Nm3 (g/hp-h) 30.7 (0.08)30.7 (0.08)33.1 (0.08)
NOx mg/Nm3 (g/hp-h) 2783.0 (6.00)2783.0 (6.00)2730.1 (5.79)
PM mg/Nm3 (g/hp-h) 28.1 (0.07)28.1 (0.07)20.4 (0.05)

Weights and Dimensions

Length
7,015 mm (276.2 in)
Width
2,558 mm (100.7 in)
Height
3,163 mm (124.5 in)
Weight
18,480 kg (40,750 lb)
Details

Note: For reference only. Do not use for installation design. Contact your account manager for precise weights and dimensions.

Ratings and Definitions

Standby
Output available with varying load for the duration of the interruption of the normal source power. Average power output is 70% of the standby rated ekW. Typical operation is 200 hours per year, with maximum expected usage of 500 hours per year.
Mission Critical
Output available with varying load for the duration of the interruption of the normal source power. Average power output is 85% of the mission critical rated ekW. Typical peak demand up to 100% of rated ekW for up to 5% of the operating time. Typical operation is 200 hours per year, with maximum expected usage of 500 hours per year.
Prime
Output available with varying load for an unlimited time. Average power output is 70% of the prime rated ekW. Typical peak demand is 100% of prime rated ekW with 10% overload capability for emergency use for a maximum of 1 hour in 12. Overload operation cannot exceed 25 hours per year. LEHE1351-11 (04/25)

Commercial Application

Standby and prime power for buildings, manufacturing, data centers and distributed infrastructure. The card helps quickly verify configuration, frequency, power, dimensions and delivery availability for a specific site.